Key result
Simplifying ECGs to extrema amplitudes reduces LVEF prediction AUROC by ~0.03 vs complete waveforms.
Why the study?
The study assessed how simplifying 12-lead ECGs affects the prediction of reduced LVEF, sex, and age.
How does simplifying 12-lead ECGs to extrema amplitudes (Eamp) or sparse binary extrema locations (Ebin) compared to complete waveforms (cWAV) affect deep learning prediction of reduced LVEF (<50%), sex, and age?
Cohort (n=28,604)
Yes
How does simplifying 12-lead ECGs to extrema amplitudes (Eamp) or sparse binary extrema locations (Ebin) compared to complete waveforms (cWAV) affect deep learning prediction of reduced LVEF (<50%), sex, and age?
Answers are grounded in this paper and cite their sources.
Although simplifying 12-lead ECGs reduces deep learning predictive accuracy compared to complete waveforms, sparse extrema locations alone retain 87.2% of performance above chance for detecting reduced LVEF (<50%) even without amplitude values.
We assessed how simplifying 12-lead electrocardiograms (ECGs) affects prediction of reduced left ventricular ejection fraction (LVEF), sex, and age. In this retrospective multicenter study, we trained one-dimensional residual networks separately for each representation in 28,604 patients. The study was not publicly registered. The prespecified primary comparison was extrema amplitudes (Eamp) versus complete waveforms (cWAV). Secondary comparisons included Ebin, a sparse binary representation of extrema locations selected by amplitude-based detection. External evaluation included 68,386 patients for reduced LVEF (<50%; 11,919 cases), 248,079 for sex, and 240,603 for age. For LVEF, site-equal areas under the receiver operating characteristic curve (AUROCs) were 0.893, 0.863, and 0.842 for cWAV, Eamp, and Ebin, respectively. Eamp had an AUROC 0.030 lower than cWAV (95% confidence interval, 0.027–0.033). Corresponding AUROCs for sex were 0.902, 0.844, and 0.764, and age mean absolute errors were 9.69, 11.15, and 12.46 years. In a post hoc comparison using the same ECGs from 34,783 patients across outcomes, Ebin retained 87.2%, 64.6%, and 63.5% of cWAV performance above chance for LVEF, sex, and age ranking, respectively. ECG simplification reduced predictive performance, but sparse extrema locations retained substantial discrimination for reduced LVEF even without amplitude values in the model input.
No takes yet. Share an insight, caveat, or question.
Makimoto et al. (2026) conducted a cohort in Reduced left ventricular ejection fraction (<50%), sex, and age prediction from 12-lead ECGs (n=28,604). Extrema amplitudes (Eamp) and sparse binary extrema locations (Ebin) 12-lead ECG representations vs. Complete waveforms (cWAV) 12-lead ECG representation was evaluated on Area under the receiver operating characteristic curve (AUROC) for predicting reduced LVEF (<50%) (AUROC difference -0.030, 95% CI 0.027-0.033). Simplifying ECGs to extrema amplitudes (Eamp) reduced LVEF prediction AUROC by 0.030 compared to complete waveforms.
Synapse has enriched 10 related papers. Consider them for comparative context: