Answers are grounded in this paper and cite their sources.
Intervertebral disc degeneration (IVDD) is one of the leading causes of low back pain and spinal malfunction. Consequently, there is a need for materials that can restore the biomechanical performance and strength of the spine. This study aimed to design and analyze a composite based on polyvinyl alcohol (PVA) modified with citric acid (CA) and incorporating nanoparticles of hydroxyapatite (nHA) for possible utilization in intervertebral disc prosthetics. An aqueous solution of PVA at 20 wt.% was synthesized and modified using 10 wt.% CA. Hydroxyapatite nanoparticles at concentrations of 1 wt.% and 1.5 wt.% were incorporated into the PVA/CA matrix. Solution casting coupled with drying was employed to prepare the composite. The structural, physicomechanical, and biological properties of the composites were evaluated using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), tensile test, Shore hardness test, swelling test, density measurement, and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test. The results obtained by XRD indicated a decrease in crystallinity following CA incorporation. Also, FTIR spectra indicated intermolecular interactions and structural modification after incorporating CA. SEM images showed relatively homogeneous morphology with acceptable nanoparticle dispersion. It was shown that the hardness increased from 47.17 in pure PVA to 83.78 for PVA/CA/nHA with 1.5 wt.% of nHA. At the same time, the swelling ratio decreased from ~108% to 95%, and density increased from 1.2634 to 1.3304 g/cm³. Compared with PVA/CA, the tensile strength exhibited a slight increase with increasing nHA content. MTT Assay showed a concentration-dependent effect on cell viability of cells, where the viability of cells for human dermal fibroblast cells (HdFn) and MG-63 cells was 74.65% and 42.79%, respectively, at the highest concentration of 400 µg/mL. Overall, the PVA/CA/nHA composites showed enhanced hardness, decreased swelling, and a concentration-dependent effect on cell viability based on the MTT assay. It is clear that the developed materials can be further researched as possible candidates for intervertebral disc applications. Nevertheless, more biomechanical tests, such as compression, cyclic, fatigue, and shear tests, must be carried out in order to test their appropriateness for possible intervertebral disc replacement applications.
No takes yet. Share an insight, caveat, or question.
Abduljawad et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: