Key result
HR-2DTTE detected larger LAD wall thickness and external diameter in CAD patients compared with normal volunteers.
Why the study?
Subclinical atherosclerosis is characterized by arterial wall thickening, compensatory arterial enlargement, and a preserved lumen. This study evaluated whether two-dimensional high-resolution transthoracic echocardiography (HR-2DTTE) can detect these changes during the asymptomatic stage of CAD.
Can two-dimensional high-resolution transthoracic echocardiography detect changes in left anterior descending coronary artery wall thickness and external diameter associated with subclinical and obstructive coronary artery disease compared with normal volunteers?
Case-Control (n=55)
Can two-dimensional high-resolution transthoracic echocardiography detect changes in left anterior descending coronary artery wall thickness and external diameter associated with subclinical and obstructive coronary artery disease compared with normal volunteers?
Two-dimensional high-resolution transthoracic echocardiography can noninvasively detect increased LAD wall thickness and compensatory enlargement in both subclinical and obstructive coronary artery disease.
Answers are grounded in this paper and cite their sources.
May support noninvasive detection of subclinical atherosclerosis; leaves open validation against gold-standard imaging before clinical adoption.
OBJECTIVES: We evaluated whether two-dimensional high-resolution transthoracic echocardiography (HR-2DTTE) can detect changes in arterial wall thickness and size associated with subclinical coronary artery disease (CAD). BACKGROUND: Arterial wall thickening, compensatory arterial enlargement and a preserved arterial lumen characterize subclinical atherosclerosis. Detection of these changes during the asymptomatic stage of CAD may allow early treatment and prevention of acute coronary events. METHODS: Twenty-six patients with angiographically proven CAD and 29 normal volunteers underwent HR-2DTTE evaluation of the left anterior descending coronary artery (LAD) using an ATL 5000 echograph (Advanced Technology Laboratories, Bothell, Washington) with a 4 to 7 MHz transducer. Significant (>70%) LAD stenosis was present in 15 patients (mean 82%); 11 patients did not have significant LAD stenosis (mean 26%) and represented a surrogate for subclinical LAD disease. Wall thickness, maximal luminal diameter and external diameter of the LAD were measured. RESULTS: Left anterior descending coronary artery wall thickness was larger in patients (1.9 +/- 0.4 mm) than it was in volunteers (0.9 +/- 0.1 mm, p < 0.001). The external diameter of the LAD was (6.0 +/- 1.1 mm) in patients and (3.9 +/- 0.7 mm) in volunteers (p < 0.001). Luminal diameter was 2.2 +/- 0.5 mm in patients and 2.1 +/- 0.6 mm in volunteers (p = NS). There was no difference in wall thickness (1.9 +/- 0.4 mm vs. 2.0 +/- 0.4 mm), luminal diameter (2.2 +/- 0.5 mm vs. 2.2 +/- 0.4 mm) and external diameter (5.9 +/- 1.0 mm vs. 6.2 +/- 1.2 mm) between the patients with <70% and >70% LAD stenosis. CONCLUSIONS: Left anterior descending coronary artery wall thickness and external diameter are significantly increased in patients with CAD as compared with normal subjects, and HR-2DTTE is sensitive enough to detect these differences. Wall thickness and external diameter are increased to the same extent in patients with obstructive and subclinical LAD disease.
No takes yet. Share an insight, caveat, or question.
Gradus‐Pizlo et al. (2001) conducted a case-control in Subclinical and obstructive coronary artery disease (CAD) (n=55). Two-dimensional high-resolution transthoracic echocardiography (HR-2DTTE) of the left anterior descending coronary artery (LAD) in CAD patients vs. Normal volunteers undergoing HR-2DTTE of the LAD was evaluated on Left anterior descending coronary artery (LAD) wall thickness (mm) (p=<0.001). HR-2DTTE detected larger LAD wall thickness and external diameter in CAD patients compared with normal volunteers.
Synapse has enriched 10 related papers. Consider them for comparative context: