Answers are grounded in this paper and cite their sources.
TiN–Ag coatings with different Ag contents were deposited on titanium bipolar plates by reactive magnetron co‐sputtering to balance corrosion resistance and interfacial conductivity in proton exchange membrane fuel cells. Increasing Ag target power from 6 to 10 W raised Ag content from 0.28 to 1.23 wt.%, reduced interfacial contact resistance (ICR), but increased corrosion current density and decreased charge‐transfer resistance. TiN–Ag (6 W) offered the best corrosion–conductivity balance among Ag‐containing coatings, with cathodic and anodic corrosion current densities of (0.666 ± 0.062) and (0.824 ± 0.147) μA·cm –2, respectively, and post‐polarization ICR below 10 mΩ·cm 2 at 1.4 MPa. XPS showed smaller changes in Ti chemical states for 6 W than for 10 W after polarization, while Ag‐containing species remained detectable. First‐principles calculations indicated that Ag incorporation reduced the work function from 7.27 to 7.08 eV and increased the TiN/Ti interfacial work of separation from 1.820 to 2.071 J·m –2. These results identify a composition‐dependent trade‐off between corrosion protection and electrical transport.
No takes yet. Share an insight, caveat, or question.
Meng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: