Answers are grounded in this paper and cite their sources.
The stress-optic coefficient is a key parameter governing the performance of optical ultrasound detectors, yet it remains unknown for many materials. Here, we develop a model based on the Lorentz–Lorenz framework that relates the stress-optic coefficient to readily measurable material properties and identifies the speed of sound as the dominant parameter. Specifically, the stress-optic coefficient is predicted to scale inversely with the square of the speed of sound. The model is validated against polymers commonly used in the ultrasound-sensing literature and shows excellent agreement with reported values. We further develop a low-frequency interferometric method for measuring silicone elastomers, whose soft nature makes characterization challenging using conventional techniques. A typical value of 0.48GPa −1 is obtained for the commonly used PDMS formulation of Sylgard 184, in general agreement with the theoretical prediction.
No takes yet. Share an insight, caveat, or question.
Kamenetsky et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: