Answers are grounded in this paper and cite their sources.
Accurate phase retrieval in a static four-quadrant wind imaging interferometer requires calibration of instrument visibilities and phase steps. We present an intensity-domain joint calibration (IJC) method based on non-linear least squares that jointly fits four-channel intensities while accommodating mean intensity variations and nonuniform phase increments. Relative intensity normalization compensates for channel response differences before fitting. For unequal relative intensity coefficients, simulations showed that the mean sum of squared phase step errors decreased from 4.1 to 0.22 deg 2 as the calibration signal-to-noise ratio increased from 30 to 90. A rotating-wheel experiment yielded a velocity root-mean-square error of 4.7 m/s across 112 individual measurements. These results support IJC calibration for interferometric phase retrieval and Doppler wind measurement.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: