Complete iron loss data for thin gauge non-oriented electrical steel (NOES) are difficult to obtain under coupled variations in frequency, magnetic flux density, temperature, and stress. This study developed a GA-XGBoost method that uses data from thicker commercial NOES grades to predict the iron loss of thinner materials. The complete 0.20 mm material group was reserved for final testing, while the 0.25–0.50 mm groups were used for model fitting and directional validation, ensuring that the test data did not enter model development. The model achieved R2 = 0.9383 and an RMSE of 16.05 W/kg on the 0.20 mm test group. It captured the overall variation in iron loss, although local errors remained at high frequency and high loss. Thickness ablation and leave-one-material-group-out analyses showed that thickness provided useful information for distinguishing material groups and predicting thin gauge loss, while its contribution also reflected differences in commercial grade and production route. SHAP analysis identified frequency and magnetic flux density as the main contributors to the model predictions. A PMSM numerical comparison further examined how errors in the predicted material loss table affected the calculated motor core loss. The proposed method can support preliminary iron loss estimation and material comparison within the investigated NOES material and operating domain.