High-resolution brain MRI acquisition is constrained by scan duration, signal-to-noise ratio, and motion sensitivity. This study developed a 2.5D super-resolution (SR) framework combining five-slice low-resolution (LR) context with contourlet-domain conditioning. A separate branch encodes the central LR slice using the nonsubsampled contourlet transform. Adaptive gates regulate its influence on spatial reconstruction. All inference inputs are LR-derived. The primary ×4 evaluation comprised 6,799 slices from 58 held-out IXI T1 subjects. The framework achieved 26.773 dB PSNR, 0.8945 SSIM, and 0.1184 LPIPS. PSNR exceeded HAT-S by 0.858 dB, with positive subject-level differences in all 58 subjects. The largest staged gain accompanied the introduction of three-slice context. Subject-level through-plane gradient error was 13.71% lower than in the 2D configuration. Budget-matched ×4 comparisons showed no PSNR advantage over the spatial control, while SSIM and LPIPS slightly favored the complete model. Under budget-matched ×2 training, contourlet conditioning increased PSNR by 0.013 dB. Processing prepared LR files to CPU SR outputs required 119.32 ms per slice, including NSCT preprocessing. External evaluation on 30 glioma subjects showed no consistent reconstruction or segmentation benefit from contourlet conditioning under matched training. These findings concern simulated LR degradation. Diagnostic benefit, lesion preservation, and robustness to actual acquisition conditions remain unestablished.