A methodology for measuring the Poiseuille coefficient of gaseous mixtures flowing through a long circular capillary using the constant-volume technique is proposed. Binary mixtures of helium argon and helium-krypton, with helium mole fractions ranging from 10% to 90%, are investigated. The temporal variation of pressure in the inlet reservoir is analytically related to the Poiseuille coefficient of the mixture, enabling its extraction from experimental pressure-time data by two methods. The measured Poiseuille coefficients show good agreement with theoretical predictions obtained from previously developed methods. In addition, new expressions are proposed for determining the viscous slip coefficient from the measured pressure variation over time. It is found that this coefficient depends strongly on the mixture composition. Finally, an efficient methodology for measuring the viscosity coefficient of the mixture is proposed. The measured viscosity values also exhibit a strong dependence on the mixture composition in agreement with previously published numerical results.
No takes yet. Share an insight, caveat, or question.
Grigorov et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: