This study investigated partial discharge characteristics of bonded epoxy resin–6061 aluminum alloy interfaces after thermal cycling. Coaxial composite insulation specimens were cycled between 20 and 120 °C. Partial discharge inception voltage (PDIV) and mean apparent charge at 15 kV were measured after 0, 5, 20, and 40 cumulative cycles. Two independent COMSOL Multiphysics 6.3 models evaluated interfacial tractions under perfect bonding and electric field distributions for prescribed maximum void thicknesses. After 40 cycles, mean PDIV decreased by 28.9%, from 13.06 to 9.28 kV, while mean apparent charge increased by 103.6%, from 527.0 to 1073.0 pC. At the end of holding, the thermomechanical model yielded a maximum normal traction of approximately 32.9 MPa and a maximum tangential traction magnitude of approximately 23.8 MPa. In the electric field model at an applied voltage of 1 kV, increasing the prescribed maximum void thickness from 0.2 to 1.0 μm raised the volume-weighted 99th-percentile electric field magnitude (E99) from approximately 0.36 to 0.53 MV/m. The experimental results demonstrate changes in partial discharge behavior after thermal cycling, while the two independent simulations help interpret these changes by examining interfacial thermal loading and electric field distributions around prescribed voids.