This case report describes a rare iatrogenic tibial nerve neuropathy following posterolateral corner (PLC) reconstruction of the knee. A 20-year-old female sustained a high-energy knee dislocation with open soft tissue injury after a scooter accident. She underwent staged management, including external fixation, skin grafting, arthrofibrosis release, and posterior cruciate ligament (PCL) fixation. Subsequent anatomic PLC reconstruction was performed using the LaPrade technique. Postoperatively, the patient developed sensory deficits and motor weakness in the tibial nerve distribution. Electrodiagnostic studies confirmed loss of tibial motor conduction. Revision surgery revealed a malpositioned popliteus graft compressing the tibial nerve. The graft was removed, neurolysis performed, and the graft repositioned anatomically in a single procedure. This case highlights the critical importance of intraoperative imaging and anatomical precision during PLC reconstruction to avoid devastating nerve complications.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.