Answers are grounded in this paper and cite their sources.
Slender reinforced concrete (RC) columns are vulnerable to instability, second-order effects, and brittle failure under axial loading. This study experimentally and numerically investigates the structural performance of slender circular RC columns strengthened with advanced jacketing systems composed of GFRP mesh embedded in high-strength mortars using engineered cementitious composites (ECC), strain-hardening cementitious composites (SHCC), or ultra-high-performance concrete (UHPC). Twelve columns were tested under monotonic axial compression, including three unstrengthened control specimens and nine externally strengthened specimens with external jacket strips of different widths and spacings. These jackets were applied to the surface of the column as external strips with three different widths of 100, 83, and 55 mm, spaced at 200, 166, and 110 mm center-to-center, respectively. All jacketing systems increased the ultimate load by 47–92% relative to the unstrengthened control column. UHPC jackets provided the highest load capacity (+92%), whereas SHCC jackets achieved the highest energy absorption (5.29 times that of the control column). A validated computer software (Abaqus model) predicted the ultimate loads within 6% of the experimental values. The model also showed that continuous full-length jacketing provides a further 21–26% capacity gain over strip jacketing.
No takes yet. Share an insight, caveat, or question.
Ghalla et al. (2026) studied this question.