This study examines crack initiation and the response to prescribed root release in arc-shaped face-end hanging roofs, using Panel 30306 of the Xuemiaotan Coal Mine as the engineering case. The intact roof was modeled as a plate clamped along two roots and free along the goaf-facing boundary. Initiation was evaluated from finite-neighborhood averaged stresses using tensile cut-off and Mohr–Coulomb shear criteria. At equal area and an aspect ratio of 1, the dimensionless initiation loads for convex-arc, triangular, and concave-arc roofs are 1.089, 1.600, and 1.997, respectively. At an aspect ratio of 3, increasing the averaging radius from 0.025L to 0.10L shifts the controlling region of the convex-arc roof from the front-root end to the middle of the side root. For the triangular roof, releasing the outer end, middle, or junction end of the side root over 40% of its initial length increases compliance by 58.89%, 36.25%, and 6.41%, respectively. The corresponding peak tensile utilizations on the retained side root at the intact initiation load are 2.93, 1.93, and 1.30. For an assumed effective thickness of 2.5 m, the thin-plate reference initiation areas under self-weight are 139, 204, and 255 m2. Accounting for transverse shear deformation increased the initiation loads by 1.0–3.6% across six matched calculations. FLAC3D results show curved stress bands near the face ends and wider yielded regions at later advance distances.