Answers are grounded in this paper and cite their sources.
The apnea–hypopnea index counts respiratory events and discards how oxygen saturation behaves around them. We modeled overnight oxygen saturation (SpO2) as a mean-reverting jump-diffusion whose jumps are the events a sleep technologist scored, so their timing is observed rather than inferred. We analyzed 24 of 25 open-access polysomnograms (3419 scored events); one recording failed a clock-alignment check. Recovery after an event had a median half-life of 20.1 s, compared with 27.8 s for return to baseline between events (ratio of 1.46, 95% confidence interval of 0.99 to 1.91; Wilcoxon p = 0.002). The pre-specified interval reaches 1, so faster recovery was not established, and an exact interval of 1.15 to 1.75 shows that the verdict turns on which interval is read. A single exponential describes the recovery poorly, explaining 27% of the variation, with a median rate of 0.094 per second over the first half of each window and approximately zero over the second. Of the 1526 recovery windows, 880 ended at the next event, and those gave faster rates. Restricted to complete windows, the ratio fell to 1.11 (0.78 to 1.48), and to 1.02 under a 3% desaturation floor. The recovery rate depends on how much of each recovery is observed.