Cancer is one of the leading causes of death worldwide, and its early detection lowers both mortality and treatment costs. Malignant cells have a higher refractive index (RI) than healthy cells, which makes label-free optical RI sensing an attractive diagnostic route. In this work, we propose a one-dimensional defective photonic crystal (1D-PC) biosensor composed of alternating perovskite strontium titanate (SrTiO 3) layers and sample-filled bio-cavities, with a thin magnesium oxide (MgO) defect layer at its centre. Transmission spectra, defect-mode wavelengths and electric-field distributions are computed with the transfer matrix method (TMM) for TE-polarized light, and the defect material, defect thickness, angle of incidence and number of periods are optimized. Replacing an SrTiO 3 defect with a low-index MgO defect increases the fraction of the resonant field energy in the bio-cavities and raises the sensitivity from 649 to 674 nm/RIU at normal incidence. Under the optimized conditions (MgO thickness 40 nm, incidence angle 85°, 15 periods per side), the defect mode shifts linearly from 1325.23 nm (normal cell) to 1422.84 nm (glioblastoma), with a sensitivity of 993–1014 nm/RIU between adjacent samples, quality factors of 2.06 × 10 5 –6.34 × 10 5, a figure of merit of up to 2.90 × 10 5 RIU −1, a detection limit of 1.7 × 10 −7 –3.5 × 10 −7 RIU and a peak transmittance above 98.9%. The sensitivity changes by less than 2.7% under ±2% layer-thickness errors and ±5 nm defect-thickness errors. We further show that machine-learning classifiers trained on six spectral features extracted from noise-augmented transmission spectra identify all nine sample types with up to 100% accuracy, and the best of them (LDA and linear SVM) remain at least 97% accurate for wavelength-calibration errors up to 0.75 nm, with a mean accuracy of 97.0% between 0.1 and 2 nm. Additional analyses show that TE polarization and complete, uniform filling of the bio-cavities are required, that the thermal drift (about −0.1 nm/K) is dominated by the sample, that water absorption in the operating band limits the Q-factor of aqueous samples unless the design is scaled to the 750–850 nm window, and that artefact-aware training keeps the classifiers accurate under realistic spectral artefacts. The proposed design is a compact, low-cost and accurate platform for label-free cancer-cell detection.
No takes yet. Share an insight, caveat, or question.
Gowda et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: