Wearable and disposable bioelectronic sensors require conductive materials that combine electrochemical performance with mechanical compliance, biocompatibility, and environmental sustainability. Yet, most bioelectronics, including those fabricated using laser-induced graphene (LIG) platforms, still rely almost exclusively on non-degradable polyimide substrates, or on transfer methods that require adhesives, solvents, or cryogenic processing. Here, we report a sustainable biosensing platform in which patterned LIG is generated on uncoated paperboard and transferred onto a glyceraldehyde-cross-linked gelatin-glycerol hydrogel by simple contact under ambient conditions, without adhesives or intermediate solvents. The porous LIG forms a continuous, gap-free interface with the hydrogel and retains its graphitic structure after transfer and nine months of ambient storage. The resulting LIG-hydrogel composite is mechanically compliant and electrochemically active, exhibiting reversible mechano-ionic and strain-dependent piezoresistive responses. Configured as a two-electrode, non-Faradaic impedance biosensor with an integrated agar reservoir, the platform discriminates Escherichia coli-containing from sterile samples within 2–3 h through bacteria-associated changes in medium impedance, with the control-bacteria separation maximized near 25 kHz (p = 0.009). This adhesive-free, ambient-processed platform offers a scalable route to environmentally sustainable, disposable, and label-free biosensors.