Answers are grounded in this paper and cite their sources.
Accurately evaluating the linear thermal transmittance (ψ) of envelope junctions requires detailed finite element method (FEM) analysis, a time-consuming and expertise-intensive process. This study proposes a method for linking insulation thicknesses extracted from architectural drawings with FEM-based ψ reference models. A total of 2576 two-dimensional FEM analyses were performed for 14 junction types, varying the insulation position (interior/exterior), thickness (30–250 mm), and thermal conductivity (0.025–0.040 W/(m·K)), yielding 28 ψ regression models with a pooled root mean square error of 0.0042 W/(m·K). Insulation regions in drawings were detected using YOLO11n-obb (mAP50 = 0.792 on image-level validation and 0.483 in project-wise cross-validation), and the insulation thickness was calculated from the detected regions by rule-based image analysis. In this first stage of the research, the junction type, insulation position, and thermal conductivity were specified manually from the drawings and design information. For two actual Type 9 junctions with exterior insulation, the ψ reference values were −0.0384 and −0.0410 W/(m·K), versus detailed FEM results of −0.0378 and −0.0567 W/(m·K); the second difference resulted from the thicker wall and the column at the corner, which the idealized reference model does not represent. These results indicate that drawing-based insulation information can be linked with ψ reference models, while the detailed geometry of actual junctions remains a limitation.
No takes yet. Share an insight, caveat, or question.
Lim et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: