Large-scale HVDC-connected wind farms are increasingly required to participate in receiving-end frequency support while maintaining wind farm AC voltage security under converter-dominated and weak-grid conditions. However, existing voltage-oriented, frequency-oriented, and event-triggered schemes are often developed separately, and their coordination through the HVDC interface is not sufficiently clarified. This paper proposes a two-layer distributed event-triggered active frequency and voltage control framework for HVDC-connected wind farms. The cluster-side layer provides local voltage support and neighbor-aware coordination, whereas the site-level layer translates receiving-end frequency stress into an HVDC-mediated coordination signal. To make the control contribution explicit, the final support law is decomposed into voltage restoration, distributed voltage coordination, HVDC-mediated frequency support, deadband-aware primary frequency response, and RoCoF-related inertia support components. An event-triggered update mechanism is further introduced to reduce unnecessary communication and controller refreshes, and a local input-to-state stability certificate of the linearized, sampled closed loop and a nonlinear proof of the absence of Zeno behavior are derived, with explicit bounds on the trigger thresholds. The proposed approach is evaluated on a nonlinear model with heterogeneous wind clusters, an energy-based MMC-HVDC link and a PLL-synchronized grid-side converter, under local voltage disturbance, receiving-end frequency disturbance, combined voltage–frequency disturbance, wind power fluctuation, and trigger-threshold sensitivity scenarios, and additionally under weak-grid faults, on the IEEE 39-bus system and for up to 50 clusters. Under combined stress conditions, the proposed controller reduces the RMS wind farm voltage error from 0.60% to 0.34%, raises the frequency nadir from 49.56 Hz to 49.75 Hz, shortens the frequency recovery time from 23.4 s to 12.1 s, and reduces the maximum RoCoF from 0.254 Hz/s to 0.238 Hz/s. Against benchmark controllers on the same plant, the proposed controller reduces the frequency index by 22–40%, at a slightly higher voltage index, relative to a decentralized consensus-and-droop scheme with counted frequency communication, in one tuning scenario and three scenarios that were not used for tuning; with gains tuned with the same budget, it is not worse than a full-information all-to-all reference configuration of the same structure that exchanges 7505 instead of 123 packets. The dynamic event-triggered communication of the decentralized benchmark reduces its packets by a similar amount, so the advantage of the proposed scheme lies in its frequency performance and not in the packet saving alone. Over 20 random plant, grid and communication uncertainty draws, the closed loop remained stable and raised the frequency nadir in every draw. The event-triggered mechanism reduces coordination updates from 7505 to 107, corresponding to a 98.6% reduction, which is relevant for communication-constrained wind farm environments. These results indicate that, in phasor-level simulation, the proposed approach is an effective and communication-efficient framework for coordinated active frequency and voltage control in HVDC-connected wind farms; its monetized cost advantage depends on the converter-aging model, and EMT and hardware-in-the-loop validation remain future work.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: