Phase change materials (PCMs) can attenuate building envelope heat transfer, but their performance depends on configuration and seasonal exposure. This study used DesignBuilder/EnergyPlus to evaluate 240 BioPCM-integrated wall configurations under Cairo’s hot desert climate, varying melting grade (Q21–Q29), thickness (1.12–7.42 cm), layer position, and wall orientation. Performance was assessed using daily net wall energy transfer, warm-season inward heat gain, signed cool-season transfer, combined seasonal thermal benefit, and surface temperatures, followed by a material-level cost comparison. Outermost PCM placement generally provided the greatest warm-season heat-gain attenuation, although cool-season effects differed by orientation. In the West-facing wall, outermost Q21 M182 reduced warm-season inward heat gain by 85.4%, while increasing cool-season outward transfer. The M182 layer reduced wall thermal transmittance from 2.000 to 1.148 W/(m2·K), corresponding to a 42.6% reduction. The West-facing wall exhibited the highest combined seasonal thermal benefit, whereas the South-facing wall favored inner-layer placement under this indicator. Q21 M182 was selected as a preferred high-performance configuration, given the small differences among closely performing melting grades. Although M182 provided the greatest combined benefit among the investigated Q21 thicknesses, M27 achieved the highest thermal benefit per unit material cost. These findings emphasize orientation-specific PCM selection and distinguish wall-level thermal performance from whole-building HVAC energy savings.
No takes yet. Share an insight, caveat, or question.
Hamied et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: