Three-dimensional (3D) additively manufactured porous metallic bone implants—such as patient-specific pelvic, acetabular, and metaphyseal prostheses—are rarely unperforated periodic lattices in clinical service. Instead, they must accommodate Ø3.5–6.5 mm locking screw tunnels, K-wire trajectories, and bone-graft fenestrations that sever load-bearing trabecular struts and distort physiological strain transfer to host bone. Current clinical practice relies on dense metallic fixation wings or surrounds each fixation hole in a porous wing with a 1.0–2.0 mm solid titanium boss; however, quantitative multi-physics benchmarks remain lacking. Here we demonstrate via 310,698-DOF 3D continuum elasticity, Crossland multi-axial high-cycle fatigue analysis, and 3D pore-scale Darcy seepage simulations that conventional solid screw bosses create a counterproductive mechanical–biological paradox: they worsen far-field 3D strain distortion beyond even an unreinforced hole (J3D=1.073 vs. 1.000), add +10.7%–19.4% titanium mass that aggravates postoperative imaging artifacts, and completely occlude radial peri-screw vascular permeability (k_r=0). To replace empirical solid sleeves without requiring patient-by-patient 3D topology optimization, we establish four closed-form engineering design guidelines grounded in a 20-architecture 3D perforation scaling law (r^2=0.989 continuum–lattice parity) and 3D vector spherical harmonic interface mechanics. Across columnar buttress lattices and clinical orthopedic Diamond (Z=4) tetrahedral scaffolds, open-pore node-flared bypass cloaks cut 3D field distortion by 28.5%–53.0%, lower peak Crossland fatigue stress by 8.1%–14.1% below bare holes with zero added mass, and preserve native-bone-level radial permeability (3.95×10⁻⁸{\ m}^2). Monte Carlo laser powder bed fusion (LPBF) tolerance audits (σ_d=38\ , ±80\ etching, 0.4\ mm drill eccentricity) confirm a 100% (80/80) win-win pass rate, while multi-activity gait sweeps (0°–90°) demonstrate omnidirectional stability (J3D≤0.50) where single-load optimization fails (J3D→1.61). In a 3D anatomical human right hemipelvis reconstruction (Enneking Type II resection, 2,380\ N Bergmann load) coupled to a 5,213-strut explicit Diamond iliac wing sub-model, our zero-optimization design outperforms all three representative traditional clinical practices—slashing periprosthetic stress shielding from 69.8% (solid Ti plate) and 64.0% (solid-boss wing) to 4.0%, elevating Frost homeostasis from 25.6%–31.5% to 86.8%, cutting explicit trabecular Crossland fatigue stress by -40.6% below solid-boss weld roots (170.0→101.0\ MPa) and -18.2% below bare holes (123.5→101.0\ MPa), and holding osteotomy micromotion to 6.0\ . Finally, cross-regime validation on a Regime II orthotropic lumbar vertebral corpectomy endoprosthesis (ORTHO_TRAB_A, λ_3=8.68) confirms identical zero-optimization performance (96.6% vertebral homeostasis, 2.5% endplate overload, -34.3% fatigue stress vs. solid bosses).
No takes yet. Share an insight, caveat, or question.
Wei et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: