Answers are grounded in this paper and cite their sources.
This study measures the residual gas permeability of concrete in two directions after drying, heating, and sustained tensile or compressive loading of plain VeRCoRs specimens. Cylindrical slices were heated without mechanical loading to temperatures from 100 to 250 °C. Whole cylinders were tested after 180-day exposures at 20 or 40 °C with compressive stresses of up to 60% of compressive strength at 50% or 100% relative humidity. Dog-bone specimens were tested after thermal exposure alone or after 14 days at 30% of tensile strength at 20, 100, or 180 °C. All permeability measurements were made after exposure and cooling on dry material. The dried cylindrical reference slices had a mean intrinsic permeability of 2.93 × 10−17 m2 in both directions. Dried dog-bone slices had longitudinal and radial means of 7.17 × 10−17 and 4.23 × 10−17 m2, respectively. At 100 °C, the radial mean with tensile loading was about twice the corresponding unloaded mean. At 180 °C, the radial measurements under tensile loading showed substantial scatter. The largest radial permeability in the compression series was 42.6 × 10−17 m2, or 14.5 times the unloaded reference, after 180 days at 60% of compressive strength, 20 °C, and 50% relative humidity. The results quantify how exposure history and flow direction influence residual permeability and identify the limits of transferring dry-specimen results to structural leakage assessments.
No takes yet. Share an insight, caveat, or question.
Dandachy et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: