This study develops an automated workflow linking parametric modeling, structural analysis, engineering checks, constrained member sizing, and component-level material and carbon accounting. The workflow evaluates five variables prioritized through the China Code Updates for Reduction of Embodied Carbon (C-CURE) initiative for 100.8 m and 201.6 m reinforced concrete office towers in Shanghai: concrete strength, reinforcement strength, office live load, load-combination factors, and column axial-compression ratio limits. All scenarios use common starting sections and a budget of 55 evaluated trials with concrete volume as the sizing objective. Carbon contributions are analyzed through the baseline carbon share of affected components and the magnitude of their changes. Lower load-combination factors yield the largest material production carbon reductions, 5.69% and 9.37%, respectively. The reductions at 100.8 m and 201.6 m are 1.78% and 3.17% for C80, 2.95% and 3.42% for HRB500, 1.16% and 1.65% for lower live load, and 3.02% and 6.15% for the exploratory axial-ratio case. Higher strength reinforcement provides consistent savings, whereas higher concrete production emissions partly offset the benefits of higher strength. Lower live load offers modest savings under fixed floor dimensions and serviceability constraints. The workflow provides a traceable basis for comparing interventions within their structural context.