β-Lactoglobulin (β-LG) may undergo changes during processing, thereby affecting immunoassay results. In this study, the Nb274–AP and Nb337–AP fusion proteins were characterized and compared as detection probes. Under the differential scanning calorimetry (DSC) conditions employed, Nb274–AP exhibited a higher thermal transition temperature than Nb337–AP. A comparison of the binding responses to heat-treated β-LG also supported the selection of Nb274–AP. Utilizing the fluorescence recovery phenomenon of the AP-triggered calcein–Ce3+ system, a secondary-antibody-free fluorescent immunoassay was developed with a detection range of 0.1563–2.5 μg/mL, a limit of detection of 0.0368 μg/mL, and recovery rates of 83.38–117.42%. After heating the β-LG model system at 105 °C for 20 min, 32.51–53.95% of the residual response in each group could still be detected. The quantification results of β-LG in 20 positive samples were in excellent agreement with those obtained using RP-HPLC and commercial ELISA kits (ICC = 0.996). Using β-LG as a marker of bovine milk adulteration, the assay quantified bovine milk in camel milk at 10–100% (R2 = 0.9915). This Nb–AP-based fluorescence immunoassay provides a viable detection strategy for monitoring β-LG in processed dairy products and assessing the authenticity of their dairy origin.