Answers are grounded in this paper and cite their sources.
Reinforced concrete (RC) frames with Autoclaved Aerated Concrete (AAC) infill are common in seismic regions, but the infill cracks at very small drifts and AAC-specific models are scarce. This paper presents a micro-to-macro modeling method based on experimentally validated micro-models and evaluates a dual strategy for reducing seismic vulnerability. A parametric study of 24 scaled frames (span, AAC thickness, and strength) provided calculation forms for the decoupled infill response; they define the AACF macro-model with Takeda column links and a central infill link with softening and cyclic degradation, consistent with the tested frame (peak +3.1%, error 6.8% of the peak). A five-storey frame was analyzed in OpenSees, base-fixed and isolated with sliding bearings and SF-ED devices, for one recorded and seven Eurocode 8 spectrum-compatible records scaled from 0.05 g to 0.80 g. The base-fixed frame reached the repairable infill drift (0.5%) at PGA = 0.17 g (recorded) and 0.24 g (spectrum-compatible), whereas with isolation the superstructure remained nearly elastic and the isolation displacement stayed within 160 mm up to about 0.55–0.7 g, depending on the device strength (6–12% of the weight) and the record. The planar analyses address one direction; the thresholds are specific to the example structure and input.
No takes yet. Share an insight, caveat, or question.
Misini et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: