Answers are grounded in this paper and cite their sources.
Magnetic shielding cylinder (MSC) serves as a foundational device by providing ultra-low magnetic environment for various frontier technologies. However, emerging application scenarios impose weight limitation that requires the reduction in shielding layer, which inherently compromises passive shielding efficiency. The MSC of fewer layers suffer from an elevated residual field limit under degaussing, whereas implementing a conventional external active compensation system to further suppress the residual field scales up the volume, thereby limiting its application scenarios. In this paper, a novel lightweight MSC is proposed, composing of a double-layer permalloy, an aluminum layer and a set of integrated external compensation coils. The residual field performance within internal cavity is optimized with pulsed magnetization regulation method based on the hysteresis characteristic of permalloy. To verify this scheme, both simulation and experiment are performed on a double-layer permalloy MSC (∅ 30 × 60 cm), the average residual field in the target region is reduced from 6.56 nT post-degaussing to 2.31 nT and exhibits excellent temporal stability. This highly integrated, lightweight magnetic shield provides valuable guiding significance for the advancement of novel hybrid magnetic shielding structures.
No takes yet. Share an insight, caveat, or question.
Jinji et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: