Background: Static computer-assisted implant surgery (s-CAIS) transfers a virtual implant plan to the patient through a surgical guide. The tissue that supports the guide (teeth, mucosa or bone) is one of the main factors that determines how closely the placed implant matches the plan. Objective: To summarise the clinical evidence on the accuracy of tooth-, mucosa- and bone-supported static surgical guides and to translate it into practical guide selection considerations. Methods: Narrative review of systematic reviews, meta-analyses and comparative clinical studies published between 2017 and 2026 that reported coronal (entry), apical and angular deviation between planned and placed implant positions according to guide support type. Results: Pooled data place the overall mean error of s-CAIS at about 1.1 to 1.2 mm at the entry point, 1.4 mm at the apex and 3.5 degrees in angulation. Tooth-supported guides were the most accurate support type in most comparisons. Bone-supported guides showed greater deviation than tooth-supported guides in two meta-analyses, while a recent retrospective clinical comparison of 180 implants found an accuracy gradient of tooth, then bone, then mucosa support. In fully edentulous mandibles, mucosa-supported guides produced the largest deviations in one retrospective multicentre series. Fully guided protocols were more accurate than pilot-drill protocols.