Answers are grounded in this paper and cite their sources.
Steam turbines in combined-cycle units are frequently involved in peak-load regulation. During startup, the differential expansion caused by the asynchronous heating of the rotor and the casing directly limits the startup speed and threatens operational safety. In this work, transient numerical simulations were conducted for both the performance-guaranteed pure condensation operating conditions and the cold startup process of a combined-cycle steam turbine. The evolution of the temperature field, stress field, and expansion difference was obtained, and a transient expansion difference prediction model for the cold start process was established. The results show that, under performance-guaranteed condensing conditions, the casing and rotor temperatures are radially uniform, thermal stress is low and system stress is dominated by centrifugal stress in the rotor. During the cold startup process, high-temperature zones are concentrated in the high- and medium-pressure steam inlet regions. Surface temperatures propagate from the steam inlet towards the exhaust. The temperature gradient and local thermal stress reach their peaks during the load ramp-up phase. During the cold startup process, both the simulated and predicted values of thermal expansion differences showed good agreement with the measured values. These results provide a theoretical foundation for the online monitoring and diagnosis of expansion errors in combined-cycle steam turbines, as well as for the optimization of startup and operating parameters.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2026) studied this question.