Answers are grounded in this paper and cite their sources.
Objective To develop an interpretable multimodal MRI radiomics-clinical model and nomogram for predicting adenomyosis lesion response to high-intensity focused ultrasound (HIFU) ablation. Materials and methods This retrospective study included 247 patients with adenomyosis treated with HIFU between September 2021 and August 2025. Based on a nonperfused volume ratio threshold of 50%, patients were classified into high- and low-ablation groups and randomly divided into training and test sets at a 7:3 ratio. Radiomic features were extracted from T2-weighted fat-suppressed, contrast-enhanced, and apparent diffusion coefficient images. Feature selection used Spearman correlation analysis, recursive feature elimination, and least absolute shrinkage and selection operator regression with 10-fold cross-validation. Clinical predictors were identified using logistic regression. A combined radiomics-clinical model and nomogram were developed. Model performance was assessed using receiver operating characteristic curves, decision curve analysis, calibration, the Hosmer–Lemeshow test, DeLong testing, and five-fold cross-validation. SHapley Additive exPlanations (SHAP) were used for model interpretation. Results Lesion-to-skin distance (OR = 0.984, 95% CI: 0.973–0.996, P = 0.009) and history of childbirth (OR = 6.403, 95% CI: 1.743–23.526, P = 0.005) were independent clinical predictors. In the test set, the combined model achieved an AUC of 0.870 (95% CI: 0.775–0.947), which was superior to the clinical model (AUC = 0.589, P < 0.001) but showed only marginal, non-significant improvement over the radiomics model (AUC = 0.868, P = 0.74). The combined model showed acceptable Hosmer–Lemeshow fit, though calibration curves showed variability attributable to test-set size. Five-fold cross-validation demonstrated stable performance, with mean AUCs of 0.876 (95% CI: 0.825–0.921) in the training set and 0.870 (95% CI: 0.755–0.958) in the test set. Conclusion The interpretable multimodal radiomics-clinical model and nomogram demonstrated acceptable performance for preoperative prediction of HIFU ablation response in adenomyosis. While clinical variables provided modest incremental value over radiomics alone, they enhanced model interpretability and clinical applicability. External validation in larger, multicenter cohorts is warranted to confirm generalizability and assess the independent contribution of clinical predictors.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: