Answers are grounded in this paper and cite their sources.
Intermodule connections (IMCs) are crucial for modular structures to sustain multihazard loading demands. This paper develops and investigates a novel grouted connection comprising inner and outer steel sleeves, which are both cast with headed studs serving as shear keys. The flexural and flexural-shear performance of full-scale grouted connection columns was experimentally evaluated under various shear-span ratios. The results indicate that the flexural capacity of the grouted connection reached 0.83 times the plastic moment resistance of the outer sleeve, 1.07 times that of the connected column, and 2.61 times that of the inner sleeve. The specimens exhibited a flexural failure mode characterized by fracture of the inner sleeve, with a ductility factor larger than 3.2, and quantified relative stiffness ratios (S j, ini / S j, rigid) ranging from 0.46 to 0.95 for no-sway frames, demonstrating superior resistance, stiffness, and ductility compared to previous studies. Validated numerical models successfully uncovered the joint’s internal force transfer mechanism via interfacial shear and localized prying forces. Based on experimental and simulation results, a calculation model and method for the flexural resistance of the connection were proposed and validated. Furthermore, an interaction envelope curve for the grouted connection under combined moment and shear force was developed, providing effective guidance for the design and verification of this novel IMC in high-rise modular structures.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: