Total knee and total hip replacements are among the most successful orthopaedic procedures, but their long-term survival remains limited by wear-related complications such as osteolysis, aseptic loosening, and the need for revision surgery. The tribological performance of these implants is governed by complex interactions between friction, lubrication, wear, contact geometry, biomaterial properties, kinematics, and load variation. International standards—ISO 14242 and 14243, as well as ASTM F732 and F3141—define loading profiles, motion trajectories, test duration, lubricant temperature, and protocols for wear quantification, but they do not explicitly require direct measurement of friction, even though friction is intrinsically linked to both wear and lubrication. This review critically examines the current standards for wear testing of joint replacements, analyses lubrication regimes that govern artificial joint performance, and evaluates the roles of friction measurement in preclinical implant assessment. Friction can be investigated using simplified tribometers (pin-on-disk and ball-on-disk), which allow rapid screening of materials and determination of lubrication regimes through Stribeck curve analysis, as well as physical simulators that reproduce in-vivo-like kinematics and load variation. Reported coefficient of friction (COF) values depend strongly on the tribological pair, protein concentration, contact conformity, surface finish, and motion trajectory; COF values for TKRs typically range from approximately 0.02 to 0.14, whereas for THRs span roughly 0.01 to 0.30 across boundary, mixed, and fluid-film regimes. Lubricants that contain proteins such as bovine serum generally increase COF relative to protein-free solutions, and friction increases progressively with accumulated wear. Surface texturing and plasma treatments have been shown to improve lubrication and reduce both friction and wear, lowering the COF by up to ∼22% and wear rates by over 50% in preliminary studies compared with smooth or untreated surfaces, even when strict contact conformity is not achieved. However, few physical simulators currently combine a realistic TKR walking cycle with simultaneous friction measurement, so results from simplified devices may overestimate biomaterial performance before clinical use. Therefore, friction measurement should be integrated into standardised wear testing protocols, particularly through servomechanical or servohydraulic simulators capable of reproducing the conditions prescribed by ISO 14243-3. Combining such physically realistic simulation with advanced analytical tools, such as one-dimensional statistical parametric mapping (1D-SPM), offers a promising route to validating surface engineering strategies and extending the clinical service life of next-generation knee and hip prostheses.
No takes yet. Share an insight, caveat, or question.
Escobar-Medina et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: