Answers are grounded in this paper and cite their sources.
Full-length weight-bearing lower limb radiography (LLR) is essential for assessing lower limb alignment; however, digital radiography (DR) systems may introduce systematic scaling errors, and evidence on United Imaging DR systems remains limited. This study aimed to evaluate the effects of such errors on angular and linear alignment parameters and their implications for alignment classification and surgical decision-making. We retrospectively enrolled 332 consecutive patients (117 male, 215 female; mean age 62.7 ± 14.6 years) who underwent LLR on the United Imaging uDR 780pro at Ningbo No. 2 Hospital between January 2020 and December 2021. A 40 mm metallic calibration ball was placed at the tibial plateau level, and the image scale ratio was calculated as its measured-to-actual diameter ratio. After excluding one outlier (Grubbs’ test), 331 cases were used for scale ratio analysis and 332 for alignment analysis. One-sample t-tests, Pearson correlation, and paired t-tests were performed, and changes in mechanical axis deviation (MAD)-based alignment classification were assessed. The mean scale ratio was 0.9744, indicating a systematic image reduction of 2.56% ( P < 0.001) that was not correlated with age, height, or body mass index (BMI). Angular parameters were unaffected, whereas linear parameters were systematically underestimated: femoral mechanical axis length by 1.07 cm (2.64%), tibial mechanical axis length by 0.89 cm (2.65%), Mikulicz line length by 1.99 cm (2.64%), and MAD by 0.20 mm (2.72%) (all P < 0.001). After correction, 11 right limbs (3.3%) and 12 left limbs (3.6%) were reclassified, all from neutral to varus or valgus. In this single-centre cohort, the United Imaging uDR 780pro full-length lower limb DR system exhibited a consistent systematic image reduction of approximately 2.56% when calibrated at the tibial plateau level, and this bias was not associated with patient age, height, or BMI. The bias does not affect angular alignment parameters but leads to systematic underestimation of linear parameters (approximately 2.6%), which may result in alignment reclassification in 3.3%–3.6% of limbs. When linear parameters are used for clinical decision-making, a correction factor (×1/0.9744 ≈ ×1.026) may be considered; however, its applicability at the hip and ankle levels requires further verification.
No takes yet. Share an insight, caveat, or question.
Sha et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: