Key result
Temporary reverse-J steering achieves ~83% technical success in target-branch catheterization without vascular complications.
Why the study?
The technique and step-specific outcomes of a temporary reverse-J maneuver using a steerable microcatheter for target-branch catheterization needed to be described.
Does a temporary reverse-J maneuver using a steerable microcatheter enable successful target-branch catheterization?
Observational (n=23)
Does a temporary reverse-J maneuver using a steerable microcatheter enable successful target-branch catheterization?
Answers are grounded in this paper and cite their sources.
A temporary reverse-J maneuver with a steerable microcatheter achieved an 82.6% technical success rate in 23 target-branch catheterizations without procedural complications or vascular abnormalities at 3-month follow-up.
PURPOSE: To describe a temporary reverse-J maneuver using a steerable microcatheter and report step-specific outcomes. MATERIALS AND METHODS: This retrospective series included 23 target-branch catheterizations performed from March 2020 to March 2026. The reverse-J maneuver was performed in every case, including all four unsuccessful cases; none was completed using direct steering alone. The deflected catheter and guidewire were withdrawn together for branch engagement. Deflection was maintained during guidewire advancement and released after adequate distal wire purchase. Technical success required advancement of the LEONIS Mova tip into the target branch. RESULTS: Guidewire entry was achieved in 21/23 cases (91.3%), and LEONIS Mova advancement in 19/23 (82.6%; exact 95% confidence interval, 61.2-95.0). In two cases, the catheter tip could not engage the target ostium and the guidewire could not enter the branch. In two others, the guidewire entered but the catheter could not advance during the transition to the released configuration. No catheter damage, vasospasm, dissection, or difficulty with catheter removal occurred. Postprocedural angiography and dynamic contrast-enhanced CT follow-up extending at least 3 months showed no maneuver-related vascular abnormality in any case. CONCLUSION: Temporary reverse-J formation followed by deflection release enabled catheterization in 19 of 23 attempts.
No takes yet. Share an insight, caveat, or question.
Okumura et al. (2026) conducted an observational in Target-branch catheterizations (n=23). Temporary reverse-J maneuver using a steerable microcatheter (LEONIS Mova) was evaluated on Technical success (advancement of the LEONIS Mova tip into the target branch) (95% CI 61.2-95.0). Temporary reverse-J steering with the LEONIS Mova microcatheter achieved technical success in 82.6% of target-branch catheterizations without vascular complications.
Synapse has enriched 10 related papers. Consider them for comparative context: