Key result
Gore Cardioform septal occluders carry a low risk of thrombosis, which typically resolves with anticoagulation.
Why the study?
The Gore Cardioform family of septal occluders is increasingly used for transcatheter PFO and ASD closure, but evidence regarding associated device-related thrombosis remains limited and fragmented, and device-specific guidelines are absent.
This narrative review summarizes the incidence, mechanisms, risk factors, and empirical management of device-related thrombosis associated with Gore Cardioform septal occluders, proposing a clinical framework for prevention, detection, and treatment.
Answers are grounded in this paper and cite their sources.
DRT with Gore Cardioform occluders warrants ongoing clinical vigilance; leaves open precise incidence and management strategies pending prospective data.
Device-related thrombosis (DRT) is a rare but potentially serious complication following transcatheter closure of patent foramen ovale (PFO) and atrial septal defect (ASD). Although the Gore Cardioform family of septal occluders is increasingly used in contemporary structural heart interventions, evidence regarding associated thrombotic complications remains limited and fragmented. In this narrative review, we systematically summarize the available literature on DRT associated with Gore Cardioform devices, including randomized clinical trials, observational studies, and published case reports. The overall incidence appears low; however, reported cases highlight a heterogeneous clinical presentation, ranging from incidental imaging findings to systemic embolic events. Thrombus formation most commonly occurs within the early post-implantation period, although late events have also been described. Potential mechanisms are multifactorial and include incomplete endothelialization, flow disturbances related to device design, and patient-specific prothrombotic conditions. Identified risk factors include hypercoagulable states, atrial arrhythmias, inadequate antithrombotic therapy or poor adherence, large defect size, and device-related factors affecting septal apposition. Current management strategies are largely empirical and typically involve systemic anticoagulation, with most cases resolving without the need for invasive intervention. In selected high-risk or refractory cases, thrombolysis or surgical removal may be required. Given the absence of device-specific guidelines, we propose a practical, clinically oriented framework for the prevention, detection, and management of suspected DRT in patients undergoing PFO or ASD closure with Gore Cardioform devices.
No takes yet. Share an insight, caveat, or question.
Plaitis et al. (2026) conducted a review in Patent foramen ovale (PFO) and atrial septal defect (ASD) with Gore Cardioform device-related thrombosis. Transcatheter closure of PFO or ASD with Gore Cardioform septal occluders was evaluated on Device-related thrombosis (DRT). Gore Cardioform septal occluders have a low incidence of device-related thrombosis, which presents early post-implantation and typically resolves with systemic anticoagulation.
Synapse has enriched 10 related papers. Consider them for comparative context: