Key result
Internal jugular access for leadless pacemakers yields ~14 percentage points fewer major vascular events than femoral.
Why the study?
The internal jugular vein is an alternative to femoral vein access for large-bore leadless pacemaker implantation, which carries bleeding risk and may be precluded by venous occlusion. However, consolidated data on the vascular safety and procedural feasibility of internal jugular vein access are lacking.
Does internal jugular vein access improve procedural feasibility and reduce major vascular access-site events compared to standard femoral vein access in patients undergoing leadless pacemaker implantation?
Meta-Analysis
Does internal jugular vein access improve procedural feasibility and reduce major vascular access-site events compared to standard femoral vein access in patients undergoing leadless pacemaker implantation?
Internal jugular vein access appears technically feasible for leadless pacemaker implantation, though current observational evidence is insufficient due to serious risk of bias to confirm whether it reduces major vascular complications compared to femoral access.
Answers are grounded in this paper and cite their sources.
Internal jugular access showed no major vascular events in small cohorts; leaves open confirmation versus femoral in randomized trials.
BACKGROUND: Leadless pacemaker (LP) implantation requires a large-bore (up to 27-French) delivery sheath. The femoral vein is the standard access route; however, it carries the risk of major bleeding and may be precluded by venous occlusion. The internal jugular vein (IJV) provides an alternative trajectory. Consolidated data on its vascular safety and procedural feasibility are lacking. METHODS: We searched PubMed, Scopus, ScienceDirect, and Web of Science through December 2025 for studies evaluating IJV-guided LP implantation. Pooled incidence rates and risk ratios (RR) for comparative cohorts were estimated using a random-effects model. RESULTS: Eleven observational studies were included after outcome-specific removal of overlapping participants. The descriptive IJV cohorts showed high reported procedural success, but definitions and denominators varied across outcomes. In two non-randomized comparative cohorts, no major vascular access-site events were reported in the IJV arms (0/132) and 17 were reported in the femoral arms (17/124). These unadjusted comparisons were at serious-to-critical risk of bias because of historical controls, baseline imbalances, differential ultrasound use, and non-standardized event ascertainment. CONCLUSION: IJV access appears technically feasible for leadless pacemaker implantation in selected adult and pediatric patients. Evidence is insufficient to determine whether it reduces vascular or overall major complications compared with femoral access. Prospective multicenter studies with standardized outcome definitions, protocolized vascular surveillance, and contemporaneous comparators are required.
No takes yet. Share an insight, caveat, or question.
Gmiński et al. (2026) conducted a meta-analysis in Leadless pacemaker implantation. Internal jugular vein (IJV) access for leadless pacemaker implantation vs. Femoral vein access was evaluated on Major vascular access-site events. Internal jugular vein access for leadless pacemaker implantation had 0% (0/132) major vascular access-site events vs 13.7% (17/124) for femoral access in two comparative cohorts.
Synapse has enriched 10 related papers. Consider them for comparative context: