Key result
Sparse-label 3D vessel segmentation achieves submillimeter accuracy and high agreement on carotid MRI.
Why the study?
Reference 3D annotations for automatic vessel segmentation training are time-consuming, and existing 2D contour annotations in double oblique planes are incompatible with current methods that learn 3D segmentation from sparse axial slices.
Does training 3D segmentation models on sparse voxel labels derived from double-oblique 2D contours and centerlines enable accurate 3D vessel lumen and wall segmentation and quantitative parameter extraction across multiple vascular imaging modalities?
Does training 3D segmentation models on sparse voxel labels derived from double-oblique 2D contours and centerlines enable accurate 3D vessel lumen and wall segmentation and quantitative parameter extraction across multiple vascular imaging modalities?
Sparse voxel labels derived from existing 2D double-oblique contours and centerlines enable accurate 3D vessel lumen and wall segmentation across MRI and CT without requiring full 3D reference annotations or pseudo-labels.
Answers are grounded in this paper and cite their sources.
Enables 3D carotid segmentation from existing 2D contours; leaves open clinical validation before workflow adoption.
Background and Objective: Accurate automatic vessel segmentation is required for disease assessment and treatment planning, yet reference 3D annotations for model training are time-consuming. Many datasets already contain 2D contour annotations in double oblique planes, created for quantitative vessel analysis, but these are incompatible with methods that learn 3D segmentation from sparse annotations in axial slices. We propose a method that transforms such contour annotations, together with the required centerline annotations, into sparse voxel labels. Unlike existing methods, it is not limited to contour annotation in axial slices, and 3D models can be trained directly on the sparse labels without pseudo-label creation. Methods: Sparse voxel labels were derived from contour and centerline annotations, with unlabeled regions assigned an ignore label, meaning these voxels do not contribute to the training loss. U-Net and UNETR architectures were trained using masked cross-entropy, masked Dice loss, and a topological loss. We evaluated our method on carotid artery black-blood (BB)-MRI, systolic and diastolic carotid 4D-flow MRI, and aortic contrast-enhanced CT, and additionally on the external test set of the carotid vessel wall segmentation challenge. We calculated the intraclass correlation (ICC) for vessel wall thickness, lumen diameter, net flow, and maximum velocity against expert annotations. Results: Our method achieved mean directed Hausdorff distances of 0.467 mm for the carotid lumen and 0.831 mm for the carotid wall in BB-MRI, and 0.665 mm for the carotid lumen at the end-diastolic time point in 4D-flow MRI. The U-Net achieved a higher Dice similarity coefficient and lower surface distances than the UNETR on all test sets, and the proposed method performed at least on par with a pseudo-label-based method trained on the same data. Extracted parameters showed ICCs of 0.71-0.98. Reducing the training annotations to 3.273% (804 instead of 24562 contours) increased the mean directed Hausdorff distance for aorta segmentation from 1.111 mm to 1.302 mm, while the mean centerline sensitivity remained at 0.997. Conclusion: Sparse voxel labels derived from annotations in double oblique planes enable 3D vessel segmentation across multiple modalities and regions. Lumen and vessel wall segmentation were achieved and quantitative parameters were successfully extracted. Vessel completeness was preserved even with very few contour annotations and with perturbed centerlines, whereas boundary accuracy degraded gradually with sparser annotations.
No takes yet. Share an insight, caveat, or question.
Rahlfs et al. (2026) studied Carotid artery and aortic vascular imaging datasets. 3D vessel segmentation (U-Net and UNETR) trained on sparse voxel labels derived from double-oblique 2D contour and centerline annotations vs. Pseudo-label-based segmentation method and expert annotations was evaluated on Mean directed Hausdorff distance, Dice similarity coefficient, and intraclass correlation (ICC) for extracted quantitative vessel parameters. Training 3D models on sparse double-oblique labels yielded mean directed Hausdorff distances of 0.467-0.831 mm in carotid MRI and ICCs of 0.71-0.98 for quantitative parameters.
Synapse has enriched 10 related papers. Consider them for comparative context: