Helium and neon are essential cryogenic working fluids for large-scale scientific facilities and other important low-temperature systems, requiring accurate density data for the design and analysis of cryogenic thermodynamic cycles and equipment. Equations of state and recent virial formulations provide efficient density references for pure helium and pure neon within validated ranges. Here, molecular dynamics (MD) simulations serve as a complementary model-assessment route to compare interaction models, semiclassical corrections, uncertainty sources, and selected three-body effects. Various two-body potentials were systematically screened using classical, Feynman-Hibbs (FH), and Wigner-Kirkwood treatments. Benchmarking against experimental data identified Czachorowski2020-FH as optimal for helium (global AARD 0.0232%) and Hellmann2021-FH for neon (AARD 0.0412%). Uncertainty assessment yielded maximum relative total expanded uncertainties of 0.026% for helium and 0.039% for neon, comparable to or lower than experimental uncertainties. Explicit three-body interactions provided additional boundary-state corrections, reducing absolute relative deviations by up to 0.011% for helium at high pressure and decreasing neon deviation from -0.134% to -0.077% at low temperature and high pressure. These results provide a consistent MD-based comparison of representative interaction models and correction schemes for pure helium and neon over the investigated temperature and pressure range.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.