A Venturi tube upstream of a micro-hydropower turbine has been proposed to compensate for low head, and a commercial computational fluid dynamics (CFD) study of a 5 kW Francis unit reported near-rated power at heads of 1.25–2.66 m. We audited the reported fields against mass and energy conservation and then ran 100 head-driven axisymmetric Reynolds-averaged Navier–Stokes (RANS) simulations (OpenFOAM, k–ω shear-stress-transport (SST), turbine as a porous momentum sink) at gross heads of 1.25, 1.93, 2.66 and 10 m for four configurations: bare penstock, upstream Venturi, downstream diffuser, and both. The reported 2.1–4.4-fold flow amplification violates continuity, and the reported pressures imply 2.8–10.9 m of head injected by a fixed-flow boundary condition; passing the prescribed 0.15 m3/s at 1.25 m actually requires 5.5 m. With the head imposed as a pressure, the Venturi never raised power: it lowered it by about 4% for a fixed machine and by 31% for a site-optimised hydraulic surrogate, and its throat reached vapour pressure at high flows. The diffuser raised power by 1.7% and 44–46%, respectively. A closed-form head-budget model reproduces all runs within 2.2%. A Venturi cannot replace head; a diffuser helps only where the exit kinetic head is a substantial fraction of the gross head.
No takes yet. Share an insight, caveat, or question.
Guerra et al. (2026) studied this question.