Answers are grounded in this paper and cite their sources.
Objective To establish an idealized three-dimensional finite-element model based on forearm computed tomography data from an 11-year-old child. Using finite-element analysis (FEA), this study investigated the biomechanical performance of transverse three-Kirschner-wire fixation for pediatric distal radial diametaphyseal junction (DMP) fractures and compared it with conventional pinning techniques, so as to provide biomechanical evidence for further experimental and clinical application of this novel fixation strategy. Materials and methods Forearm CT datasets from a healthy 11-year-old boy and 2.0-mm Kirschner-wire parameters were imported into dedicated software. A standardized DMP transverse fracture model was constructed. Four finite-element assemblies were generated: transverse three-Kirschner-wire group, transverse two-Kirschner-wire group, parallel Kirschner-wire group, and crossed Kirschner-wire group. Six loading scenarios (30 N flexion, 30 N extension, 30 N compression, 30 N distraction, 1 N·m internal rotation, and 1 N·m external rotation) were simulated in ANSYS Workbench. Fracture-fragment relative displacement and Kirschner-wire stress distribution were compared across groups. Results Under all six loading conditions, the transverse three-wire group yielded the smallest maximum fracture-fragment displacement (0.888 mm, 0.888 mm, 0.496 mm, 0.497 mm, 0.000257 mm, 0.000257 mm, respectively). Under flexion, extension, internal-rotation and external-rotation loads, the parallel-wire group produced the lowest peak Kirschner-wire stress (456.8 MPa, 457.31 MPa, 0.639 MPa, 0.639 MPa). Under compression and distraction, the transverse three-wire group exhibited the lowest wire stress (241.83 MPa and 241.45 MPa). Conclusion In this single-sample idealized FEA simulation, transverse three-Kirschner-wire fixation produced the smallest fracture-end displacement, indicating superior fracture stability. Although this configuration only achieved the lowest peak wire stress under compression and distraction, stress contour plots demonstrated multi-point, relatively homogeneous stress dispersion, with absolute stress values that showed only limited differences from those of the other groups, indicating satisfactory fixation strength within an acceptable range. These are purely computer-simulated findings and cannot substitute clinical outcomes. Further cadaveric biomechanical tests and large-scale clinical investigations are required for validation.
No takes yet. Share an insight, caveat, or question.
Wan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: