We develop a compact motor-imagery (MI) EEG decoder and examine its classification performance and computational cost. Compact SC-LIF combines factorized temporal–spatial convolutions with channel-adaptive spike-count leaky integrate-and-fire neurons. The primary BCI Competition IV 2a comparison evaluates six models using common input trials, identical training-session validation folds, equal search budgets, and three final seeds. Additional experiments examine BCI Competition IV 2b, Zhou2016, architectural components, and channel and neuron settings. Compact SC-LIF achieves 71.91 ± 12.93% subject-level accuracy and 71.72% macro-F1 with 3,508 parameters and 6.45 million dense synaptic MACs per trial. Accuracy differences from EEGNet and FBCNet are not significant; gains over corrected PLIF-SNN, Deep4Net, and ShallowFBCSPNet range from 8.24 to 10.10 percentage points (Holm-adjusted p = 0.0195). Separate fixed-protocol controls attribute a 29.0% reduction in counted operations to front-end factorization, while the matched backend comparison does not establish an independent SC-LIF accuracy gain. The decoder combines a small parameter count with competitive MI classification under a defined evaluation protocol. Its computational savings are architectural; dense synaptic counts exclude neuron-state and memory costs and do not represent measured hardware energy.