Answers are grounded in this paper and cite their sources.
To address structural wear, this paper proposes a bearing hinge wear simulation method based on the Archard wear model. The dynamic control of node displacement is achieved using the UMESHMOTION subroutine, enabling the simulation of the wear evolution process on the material surface. Initially, the reliability of the method is verified by comparing the bearing wear simulation results with those found in existing literature. Subsequently, the wear response of the hinge structure under varying load and initial clearance conditions is systematically analyzed using this method. The results indicate that the load magnitude is strongly positively correlated with the wear depth. When the load increases from 1000 N to 3000 N, the maximum wear depth increases from 0.01274 mm to 0.03557 mm. Furthermore, the presence of initial clearance exacerbates contact impact and sliding, with larger clearances leading to more significant material loss. For instance, when the initial clearance increases from 0.02 mm to 0.35 mm, the maximum wear depth increases from 0.0143 mm to 0.03213 mm.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.