Answers are grounded in this paper and cite their sources.
Historic unreinforced masonry (URM) buildings with flexible timber floors are seismically vulnerable because diaphragms deform in plane and wall–floor connections are often inadequate. In practice, strengthening may be limited to the attic or an asymmetric part of a storey. This study compares fourteen three-dimensional equivalent-frame models of two Zagreb URM building types through 336 nonlinear static analyses using the N2 method. A cross-laid 2 × 30 mm glued-laminated timber panel and an 80 mm timber–concrete composite slab were modelled at the attic only, at the attic and half of an intermediate floor, or at all levels above the basement. Separately, 144 joist cross-section/span combinations were assessed for ultimate and serviceability limit states under vertical actions. For TYPE A, attic-only strengthening increased the X-direction seismic resistance index (αSD) by 22.2% but reduced its Y-direction value by 27.3%. For TYPE B, comprehensive strengthening increased the minimum index by 40% (timber) and 32% (composite). Both vertical limit states were satisfied by 47.9%, 68.8%, and 84.7% of combinations for original, timber-strengthened, and composite-strengthened joists, respectively. For the analysed models, and assuming effective wall–floor connections, intervention continuity and distribution governed the global response more strongly than nominal diaphragm stiffness, while the resistance of the unstrengthened walls remained critical.
No takes yet. Share an insight, caveat, or question.
Volarić et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: