Answers are grounded in this paper and cite their sources.
In heat transfer tubes equipped with vortex generators (VGs), the enhancement of heat transfer was accompanied by a severe increase in flow resistance. In this study, VGs were strategically placed in the upstream and downstream sections of a circular tube, with different VG densities prescribed in each region. Accordingly, two innovative VG placement strategies were proposed, namely front dense rear sparse (FDRS) and front sparse rear dense configurations, respectively. These hierarchical pitch configurations were designed to enhance the overall thermo‐hydraulic performance by reducing flow resistance, compared with the conventional uniform pitch configuration. Numerical simulations were conducted to investigate the effects of these configurations on flow and heat transfer characteristics under turbulent flow. The results showed that the FDRS configuration enhanced vortex generation and intensified boundary layer disturbance in the upstream section of the test section, while the downstream section experienced a significant reduction in flow resistance. Through the sweeping motion of the longitudinal vortices induced by the VGs, intense mixing between the hot fluid near the wall and the colder core flow was enhanced. This result demonstrated the superior performance of FDRS configuration over the entire investigated flow regime.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2026) studied this question.