We report the design, fabrication, and performance of a kilogram-scale, laser-driven annular photoreactor for preparative photochemistry. Building on a previously reported 0.5 W light-diffusing-fiber (LDF) prototype, we increased reactor volume ∼8× and scaled delivered optical power by ∼1600× by employing a different LDF and an 800 W diode laser. Externalizing photon generation keeps electrical and heat-generating components remote from hazardous chemical environments, facilitating the use in ATEX-rated facilities, and enables full enclosure of the emitted light for improved operational safety. The prototype was evaluated on a nickel-catalyzed C–N cross-coupling, delivering high, reproducible conversions across a range of flow rates, optical powers, and photocatalyst concentrations. Compared with a benchmark LED-driven tubular photoreactor, the present design increased the efficiency of delivered photon utilization within the reactor volume by ∼3×. A mechanistic PDE model was applied to accurately predict conversion across the ∼1600× scale-up in laser power (parity R2 = 0.981). These results indicate that laser-driven annular photoreactors offer a safe, controllable, and scalable platform capable of a model-projected multikilogram-per-day photochemical production suitable for small-molecule pharmaceutical manufacturing.