Answers are grounded in this paper and cite their sources.
The thermal sensitivity of crystalline silicon photovoltaic (PV) cells reduces efficiency, especially in building-integrated photovoltaic (BIPV) systems with insulated rear surfaces. A two-dimensional transient finite element method (FEM) model was developed using the MATLAB PDE Toolbox and the effective heat capacity method to simulate phase change material (PCM)-based cooling. Three cases were studied: reference PV, PV with pure phase change material (PCM) RT35, and PV with aluminium foam-enhanced phase change material (PCM) at 5%, with thicknesses from 10 to 30 mm over 180 minutes. Both PCM cases reduced PV temperature. At 30 minutes, the enhanced PCM at 30 mm reached 42.91 degrees C, about 20 degrees C lower than the reference. A thermal crossover occurred at about 90 minutes, after which the pure PCM performed better. Before the crossover, efficiency improved to about 13.2% for the enhanced PCM and 13.1% for the pure PCM, compared to 12.3% for the reference at 60 minutes. The required thickness depended on exposure time: 20 mm sufficed for short exposures, while 30 mm was needed for longer operation. The model shows that the MATLAB PDE Toolbox is an efficient alternative to computational fluid dynamics (CFD) tools for analysing photovoltaic phase change material (PV PCM).
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: