Background Accurate quantitative 177 Lu SPECT imaging is critical for reliable absorbed dose calculation in radiopharmaceutical therapy (RPT). Gamma cameras equipped with solid‐state cadmium zinc telluride (CZT) detectors have demonstrated enhanced sensitivity and energy resolution compared with conventional gamma cameras with NaI(Tl) detectors. However, the impact of energy window selection and reconstruction parameters on quantitative performance has not been systematically characterised. This study systematically evaluates the impact of energy window configuration, reconstruction algorithm, and update scheme on quantitative performance for 1 7 7 Lu SPECT imaging using a StarGuide CZT SPECT/CT system, with performance assessed in terms of calibration factor stability, image noise, recovery coefficients, and lesion detectability. Methods Four 177 Lu phantom configurations were employed: (1) a large uniform cylinder (∼6800 mL) for calibration factor (CF) determination and noise analysis, (2) a second uniform cylinder (∼6300 mL) for independent large‐volume quantification, (3) a NEMA IEC Body Phantom with hot spheres in a cold background for small‐volume quantification and partial volume correction (PVC), and (4) the same NEMA phantom with hot spheres in a warm background for tomographic contrast and lesion detectability. CFs were determined for the 113 keV, 208 keV, and combined energy windows across 270 reconstruction configurations (3 algorithms: Q.Clear + RDP, Q.Clear, OSEM; 3 subsets: 5, 10, 15; 10 iteration counts: 2–20 in steps of 2). Noise was quantified by the coefficient of variation (CoV), small‐volume quantification by recovery coefficient (RC) and PVC, contrast and detectability by the contrast recovery coefficient (CRC) and contrast‐to‐noise ratio (CNR), applying the Rose criterion (CNR ≥ 5). Clinical applicability was illustrated in one patient imaged at three dosimetry time points. Results Mean CFs were 243.88 ± 1.30, 90.88 ± 0.34, and 333.53 ± 1.91 cps/MBq for the 113 keV, 208 keV, and combined energy windows. Large‐volume quantification on the second cylinder was accurate within 1.17% for all window configurations. CFs were stable across most reconstruction configurations but underestimated at low update counts, with deviations up to 4.43% at 2i5s for 208 keV. Image noise increased with higher iterations and subsets for Q.Clear and OSEM, whereas Q.Clear + RDP maintained stable noise levels (CoV 5.12%–9.97%) for 113 keV and combined windows. PVC substantially improved small‐volume quantification, restoring accuracy to within ± 5% for spheres ≥ 17 mm. Q.Clear + RDP achieved the highest CNR despite slightly lower CRC, maintaining CNR above the Rose threshold for spheres ≥ 17 mm, with the 13 mm sphere near the detection threshold. In the patient, an isolated lesion remained visually distinct across all three dosimetry time points, including the lowest‐count acquisition. Conclusion Under the conditions studied, the combined energy window with Q.Clear + RDP reconstruction, together with energy‐window‐specific PVC, provided the best overall balance of sensitivity, quantitative accuracy, and lesion detectability for 177 Lu SPECT on our StarGuide system. A minimum of 10 iterations with 10 subsets is recommended to ensure adequate convergence. These results support a standardised, validated workflow for 177 Lu SPECT quantification and personalised dosimetry for our facility.
No takes yet. Share an insight, caveat, or question.
Banda et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: