Answers are grounded in this paper and cite their sources.
Prestressed concrete (PSC) beam ends deteriorate faster when they are located underneath bridge deck expansion joints. Traditionally, inspection and maintenance decisions rely on subjective assessments of deterioration and often lack correlation with structural capacity. This paper presents a capacity-based condition matrix to support condition-state (CS) and request-for-action (RFA) decisions on deteriorated I-shaped PSC beam ends. A detailed methodology based on the strut-and-tie method was developed to assess beam-end capacity under various deterioration scenarios. The margin of safety and capacity-to-demand ratio were evaluated using experimental results and in-service bridge details, respectively. Sensitivity analyses were conducted, and a 15% capacity reduction was established as a threshold for RFA submission. According to the analysis results, capacity reduction is approximately proportional to the percentage of strands that are exposed while section loss or bearing area loss without exposed strands do not affect the beam-end shear capacity. The capacity-based beam-end condition matrix is a significant contribution to the state of the art and practice compared with the qualitative classifications or ratings given in current specifications and guidelines. This matrix streamlines the process of assigning CSs and RFA submissions, improving structural safety while minimizing unnecessary inspections and repairs.
No takes yet. Share an insight, caveat, or question.
Bhowmik et al. (2026) studied this question.