Answers are grounded in this paper and cite their sources.
Fully glazed façades often cause overheating and heavy air-conditioning use in hot climates. This study investigates how a simulation-driven adaptive design approach can improve thermal comfort behind an existing glazed façade, using the southwest curtain wall of the Faculty of Engineering at Damanhour University, Egypt, as a case study. The methodology combined field observation, temperature measurements and occupant interviews with parametric simulation (Rhino, Grasshopper, Ladybug, Honeybee/EnergyPlus). Three configurations of a representative office were compared: the existing façade, vertical fins, and an egg-crate system of horizontal overhangs with vertical fins. Performance was judged by annual operative temperature and the share of occupied hours within the adaptive comfort zone. Comfort hours rose from 2% in the baseline to 11% with vertical fins and 25% with the egg-crate system, which cut peak operative temperature by 6 °C. Shading geometry must match façade orientation, and the workflow is replicable for retrofitting glazed buildings in hot climates.
No takes yet. Share an insight, caveat, or question.
Shousha et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: