Key result
Trisomy 21 fetuses show lower tricuspid A-wave velocities and higher E/A ratios at 11–13 weeks.
Why the study?
The study aimed to investigate first-trimester tricuspid Doppler characteristics in normal and trisomy 21 fetuses and assess their associations with nuchal translucency.
Does first-trimester tricuspid valve Doppler assessment identify differences in tricuspid inflow patterns and associations with nuchal translucency between trisomy 21 and normal fetuses?
Observational (n=529)
Does first-trimester tricuspid valve Doppler assessment identify differences in tricuspid inflow patterns and associations with nuchal translucency between trisomy 21 and normal fetuses?
First-trimester tricuspid inflow patterns differ between normal and trisomy 21 fetuses, with trisomy 21 fetuses exhibiting lower A-wave velocities and a higher E/A ratio.
Answers are grounded in this paper and cite their sources.
May support refined first-trimester trisomy 21 risk assessment; leaves open incremental value over NT in prospective cohorts.
OBJECTIVE: To investigate first-trimester tricuspid Doppler characteristics in normal and trisomy 21 fetuses and assess their associations with nuchal translucency (NT). METHODS: We retrospectively analyzed singleton pregnancies examined between 11 + 0 and 13 + 6 weeks of gestation. Tricuspid E- and A-wave velocities and the E/A ratio were measured using pulsed-wave Doppler. Group comparisons were performed using Welch's t-test and multivariable linear regression adjusted for crown-rump length and fetal heart rate. Interactions between trisomy 21 status and NT expressed as multiples of the median (NT-MoM) were also assessed. RESULTS: Among 529 fetuses (517 normal, 12 trisomy 21), E-wave velocity increased with crown-rump length in normal fetuses. NT-MoM was weakly associated with E-wave velocity and E/A ratio after adjustment. These associations were not significant in fetuses with trisomy 21. Compared with normal fetuses, trisomy 21 fetuses had lower A-wave velocities and a higher E/A ratio; E-wave velocity did not differ significantly. The interaction between trisomy 21 status and NT-MoM was significant for the E/A ratio, but not after excluding two trisomy 21 fetuses with NT-MoM > 4.5. CONCLUSION: Tricuspid inflow patterns may differ between normal and trisomy 21 fetuses. Findings in trisomy 21 are exploratory, given the small sample size and coexisting structural heart defects.
No takes yet. Share an insight, caveat, or question.
Akiba et al. (2026) conducted an observational in Trisomy 21 and normal first-trimester pregnancies (n=529). Trisomy 21 status vs. Normal fetuses was evaluated on Tricuspid E- and A-wave velocities, E/A ratio, and their associations with nuchal translucency (NT-MoM). Trisomy 21 fetuses (n=12) had lower tricuspid A-wave velocities and higher E/A ratios compared with normal fetuses (n=517) between 11+0 and 13+6 weeks of gestation.
Synapse has enriched 10 related papers. Consider them for comparative context: