Key result
LIGHT-plane supra-annular TAVR sizing yields ~100% device success with frequent downsizing in type 0 BAV.
Why the study?
In Sievers type 0 bicuspid aortic valve, conventional annular sizing for TAVR may fail to identify the anchoring and sealing level, contributing to worse clinical outcomes compared to tricuspid anatomy.
Does supra-annular sizing at the LIGHT plane improve procedural and in-hospital VARC-3 outcomes for TAVR in patients with Sievers type 0 bicuspid aortic valve and severe aortic stenosis?
Observational (n=8)
No
Does supra-annular sizing at the LIGHT plane improve procedural and in-hospital VARC-3 outcomes for TAVR in patients with Sievers type 0 bicuspid aortic valve and severe aortic stenosis?
A novel supra-annular TAVR sizing method at the LIGHT plane in Sievers type 0 bicuspid aortic valve patients led to prosthesis downsizing in 62.5% of cases with 100% technical and device success.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for LIGHT plane sizing in Sievers 0 BAV TAVR; prospective trials needed before clinical adoption.
Background As transcatheter aortic valve replacement (TAVR) expands to younger and lower-risk populations, the proportion of patients with bicuspid aortic valve (BAV) anatomy undergoing transcatheter treatment is increasing. In Sievers type 0 BAV, due to the peculiar anatomy, the conventional annular sizing may fail to identify the anchoring and sealing level, contributing to worse clinical outcomes after TAVR in comparison to tricuspid anatomy. Our study aims to introduce and evaluate a novel supra-annular sizing approach for type 0 BAV based on the identification of the “LIGHT” (Level of Implantation at the neo- hinGe Height in Type 0 BAV) plane defined by native leaflet dynamics and possibly representing the level of maximal prosthesis-leaflet interaction. Methods Eight consecutive patients with type 0 BAV and severe aortic stenosis underwent TAVR using supra-annular self-expanding valves sized according to the perimeter measured at the LIGHT plane. Procedural and in-hospital outcomes were assessed according to the Valve Academic Research Consortium- 3 (VARC-3) criteria. Results Sizing based on the LIGHT plane perimeter resulted in prosthesis downsizing in 5 patients (62.5%). Technical success and device success were achieved in all patients (100%). There were no deaths, annular ruptures, strokes, or major vascular complications. The median post-procedural transvalvular gradient was 8.0 mmHg (5.5–10.5). One patient (12.5%) required permanent pacemaker implantation. Conclusions The LIGHT plane sizing approach for TAVR in type 0 BAV was feasible and safe in this preliminary experience. This anatomy-driven approach may improve TAVR outcomes in this challenging subset.
No takes yet. Share an insight, caveat, or question.
Ricchetti et al. (2026) conducted an observational in Sievers type 0 bicuspid aortic valve and severe aortic stenosis (n=8). Supra-annular TAVR sizing at the LIGHT plane with self-expanding Evolut valves was evaluated on VARC-3 technical success and device success. Supra-annular TAVR sizing at the LIGHT plane resulted in prosthesis downsizing in 62.5% of Sievers type 0 BAV patients and achieved 100% technical and device success with no moderate or severe PVL.