Key result
Guideline-recommended 150 Hz ECG filtering yields higher QRS amplitudes and increases J-wave detection vs. 35 Hz.
Why the study?
Large-scale pediatric ECG reference values using guideline-recommended filter settings are lacking in Japan, and the effects of lower low-pass cutoff filters on QRS amplitudes have not been well clarified.
Does recording 12-lead ECGs with guideline-recommended filter settings (150 Hz low-pass) alter reference QRS amplitudes and J-wave prevalence compared to lower low-pass filter settings (35 Hz) in Japanese school-age children and adolescents?
Cross-Sectional (n=30,256)
Yes
Does recording 12-lead ECGs with guideline-recommended filter settings (150 Hz low-pass) alter reference QRS amplitudes and J-wave prevalence compared to lower low-pass filter settings (35 Hz) in Japanese school-age children and adolescents?
Establishes Japanese pediatric 12-lead ECG reference values using guideline-recommended 150 Hz low-pass filters, demonstrating significantly deeper Q and S waves and higher R waves and J-wave prevalence than previously documented with 35 Hz filters, which calls for revising current school-based screening criteria for abnormal Q waves.
Answers are grounded in this paper and cite their sources.
May warrant updated pediatric ECG norms with 150 Hz filtering; extends prior references while leaving screening accuracy effects open.
Background Reference values of electrocardiographic (ECG) findings with guideline‐recommended filters (hereafter, without filters) from a large number of pediatric subjects are lacking in Japan. The effects of lower low‐pass cutoff filters (with filters) on QRS amplitudes have not been well clarified. Methods A total of 60 406 pediatric participants' ECGs without filters at school‐based screening programs were obtained between 2016 and 2021. Each ECG was manually checked by 2 pediatric cardiologists, and only ECGs with sinus rhythm were included. Baseline drift, artifacts, and noise that could affect the automatic measurement of PQRS amplitudes and durations were observed in 24 588 ECGs and thoroughly excluded. Finally, 30 256 ECGs of 7372 first graders (boys/girls = 3784/3588), 8910 seventh graders (4300/4610), and 13 974 10th graders (6852/7122) were analyzed. ECG parameters without filters were determined and compared with those of previous data with filters. Results ECG parameters without filters were newly established. The difference in QRS amplitudes between the present and previous data followed the order of Q > S > R waves, right > mid‐ > left precordial leads for R waves, and left > mid‐ > right precordial leads for S waves. The difference in amplitude was more marked in girls than in boys. The prevalence of J wave also differed substantially between the two studies. Conclusions This study established the reference values for ECG parameters without filters. The differences between the two studies may have been influenced not only by filter settings but also by differences in study populations and recording conditions.
No takes yet. Share an insight, caveat, or question.
Yoshinaga et al. (2026) conducted a cross-sectional in Healthy school-age children and adolescents undergoing school-based ECG screening (n=30,256). 12-lead ECG recorded with guideline-recommended filter settings (low-pass filter 150 Hz, high-pass filter 0.05 Hz) vs. Previous study data using lower low-pass cutoff filter settings (low-pass filter 35 Hz, high-pass filter 0.5 Hz) was evaluated on Reference values for ECG parameters (P, Q, R, S, STJ, T waves, intervals, and notch-type J-wave prevalence) without low-pass amplitude attenuation. Guideline-recommended 150 Hz ECG filtering yielded higher Q, S, and R wave amplitudes (especially in girls) and a 1.04% to 5.60% notch-type J-wave prevalence compared to 35 Hz filtering.